Tyvärr kunde vi inte logga in dig.
Kontrollera e-postadress och lösenord.
Leveransinformation
The basket of your last visit to Black Box is still available.
Vänligen skapa ett konto för att fortsätta.
The Black Box website uses cookies. By continuing the use of the Black Box website, or by pressing the agree button on the right, you consent to the use of cookies on this website.
Mer information.
One of the most important cable measurements is Near-End Crosstalk (NEXT). It’s signal interference from one pair that adversely affects another pair on the same end. Crosstalk occurs between adjacent wire pairs (“pair-to-pair NEXT”). In addition, all other pairs in a UTP cable can also contribute their own levels of both NEXT and Far-End Crosstalk (FEXT), multiplying the adverse effects of interference onto a transmitting or receiving wire pair. These compounded levels of interference can prove crippling. So check your NEXT ratings on any CAT5e and CAT6 cable you purchase.
Near-End Crosstalk (NEXT) NEXT measures an unwanted signal transmitted from one pair to another on the near end.
Power Sum Near-End Crosstalk (PS-NEXT)
PS-NEXT measures the unwanted signals from multiple pairs at the near end onto another pair at the near end.
Far-End Crosstalk (FEXT)
FEXT measures an unwanted signal from a pair transmitting on the near end onto a pair at the far end. Full-duplex operation is taken into account where signals are generated simultaneously on both ends.
Power Sum Equal-Level Far-End Crosstalk (PS-ELFEXT)
PS-ELFEXT measures the total sum of all interference from pairs on the far end onto a pair on the near end without the effects of attenuation.